When starting FME Server you may not be able to log onto the User Interface and may receive error messages similar to "Lost communication with Server",“无法连接”。
Reviewing the FME Server logs you identify error messages in the processMonitor*****.log that contain something like:
"java.net.BindException: Address already in use: bind"
This typically indicates that some of the FME Server processes did not shut down properly during the restart of FME Server.
The only resolution at this point is to terminate the processes with one of the following methods.
A.Task Manager
B..bat script
Create a .bat script that terminates the all FME processes,after shutting down the services.Use the taskkill command similar to this example:
taskkill /im FMEServer.exe /f
C.Restart the Operating System
This should clear up the processes and allow FME Server to start in a good state.